How do you determine how many raw deep coil is required in an AHU?
The raw deep coil requirement for an air handling
unit (AHU) is determined based on several factors, including the desired
cooling capacity, the entering air temperature and humidity, and the required
leaving air temperature and humidity.
Here are the steps to determine the raw deep coil
requirement for an AHU:
1. Determine the cooling capacity: The cooling capacity of the AHU is the
amount of heat that needs to be removed from the air. It is usually expressed
in units of tons of refrigeration (TR) or in watts (W). The cooling capacity
can be calculated based on the desired temperature and humidity conditions of
the entering and leaving air.
2. Select the refrigerant: The type of refrigerant that will be used in the
AHU is an important factor in determining the raw deep coil requirement.
Different refrigerants have different thermodynamic properties, which can
affect the performance of the coil.
3. Calculate the surface area of the coil: The surface area of the coil is
a key factor in determining the raw deep coil requirement. The larger the
surface area, the more heat can be absorbed from the air. The surface area can
be calculated based on the desired cooling capacity and the properties of the
refrigerant.
4. Determine the fin spacing: The fin spacing of the coil affects its
performance by determining the rate at which air can pass over the coil. The
fin spacing should be selected based on the desired air flow rate, the
refrigerant properties, and the size and type of fan used in the AHU.
5. Choose the tube size: The tube size of the coil affects the amount of
refrigerant that can flow through it, which in turn affects the cooling
capacity of the coil. The tube size should be selected based on the desired
cooling capacity, the refrigerant properties, and the available space in the
AHU.
6. Select the type of coil: There are several types of coils that can be
used in an AHU, including finned tube coils, plate and frame coils, and
tube-in-tube coils. The type of coil selected will depend on the desired
cooling capacity, the available space in the AHU, and the cost and maintenance
requirements of the different types of coils.
In conclusion, determining the raw deep coil requirement for an AHU
requires a detailed analysis of the desired cooling capacity and the design
parameters of the AHU. It is best to consult with a HVAC engineer or a
refrigeration specialist to ensure that the right raw deep coil is selected for
the application.